Low Temperature Chamber DWY-60A
-
Price:
Negotiable
- minimum:
- Total supply:
-
Delivery term:
The date of payment from buyers deliver within days
-
seat:
Beijing
-
Validity to:
Long-term effective
-
Last update:
2017-12-06 07:31
-
Browse the number:
66
+
TIME Group Inc.
- Contactaixin:
Ms. Sabrina Ni(Mr.)
- Email: telephone: phone:
-
Arrea:
Beijing
Address:No. 28, Shangdi West Road, Haidian District, Beijing, China 100085
- Website:
+
DWY-60A low temperature chamber
DWY-60A low temperature chamber is designed according
to the requirements in Test Method of Charpy impact tests for metals. It has the features of non chemical pollution, low noise, compact in dimension, easy operate and high accurate of temperature control. It is the ideal equipment for low temperature impact test for metals. Beside, this machine is applicable for other tests and inspection which require the low temperature condition.
DWY-60A low temperature chamber is designed according
to the requirements in Test Method of Charpy impact tests for metals. It has the features of non chemical pollution, low noise, compact in dimension, easy operate and high accurate of temperature control. It is the ideal equipment for low temperature impact test for metals. Beside, this machine is applicable for other tests and inspection which require the low temperature condition.
Specification | DWY-60A | ||||||||
Temperature range | : | Room temperature to -60ºC | |||||||
Temperature accuracy | : | <±0.5ºC | |||||||
Cooling rate | : | 0ºC to -20ºC (approx. 1.5ºC/min) | |||||||
: | -20ºC to -40ºC (approx. 1.0ºC/min) | ||||||||
: | -40ºC to -600ºC (approx. 0.7ºC/min) | ||||||||
Dimension (mm) | : | 900 x 505 x 850 | |||||||
Chamber dimension (mm) | : | 120×120×70 | |||||||
Specimen quantity | : | > 60 (10 x 10 x 55 mm specimen) | |||||||
Counter | : | 1S ~ 99min. Resolution: 1min | |||||||
Colling media | : | Ethanol or other antifreezen liquids | |||||||
Expansion Valve | : | From Danfoss | |||||||
Power supply | : | 220V~240V, 50Hz, 3KW | |||||||
Stirring motor power | 16W |
Specification | DWY-60A | ||||||||
Temperature range | : | Room temperature to -60ºC | |||||||
Temperature accuracy | : | <±0.5ºC | |||||||
Cooling rate | : | 0ºC to -20ºC (approx. 1.5ºC/min) | |||||||
: | -20ºC to -40ºC (approx. 1.0ºC/min) | ||||||||
: | -40ºC to -600ºC (approx. 0.7ºC/min) | ||||||||
Dimension (mm) | : | 900 x 505 x 850 | |||||||
Chamber dimension (mm) | : | 120×120×70 | |||||||
Specimen quantity | : | > 60 (10 x 10 x 55 mm specimen) | |||||||
Counter | : | 1S ~ 99min. Resolution: 1min | |||||||
Colling media | : | Ethanol or other antifreezen liquids | |||||||
Expansion Valve | : | From Danfoss | |||||||
Power supply | : | 220V~240V, 50Hz, 3KW | |||||||
Stirring motor power | 16W |
Specification | DWY-60A | ||||||||
Temperature range | : | Room temperature to -60ºC | |||||||
Temperature accuracy | : | <±0.5ºC | |||||||
Cooling rate | : | 0ºC to -20ºC (approx. 1.5ºC/min) | |||||||
: | -20ºC to -40ºC (approx. 1.0ºC/min) | ||||||||
: | -40ºC to -600ºC (approx. 0.7ºC/min) | ||||||||
Dimension (mm) | : | 900 x 505 x 850 | |||||||
Chamber dimension (mm) | : | 120×120×70 | |||||||
Specimen quantity | : | > 60 (10 x 10 x 55 mm specimen) | |||||||
Counter | : | 1S ~ 99min. Resolution: 1min | |||||||
Colling media | : | Ethanol or other antifreezen liquids | |||||||
Expansion Valve | : | From Danfoss | |||||||
Power supply | : | 220V~240V, 50Hz, 3KW | |||||||
Stirring motor power | 16W |